Skip to content

System Log Extended Function

Overview

The system log can be expanded by setting the parameter "Rds.json". It is possible to record whether the request is from the API, the site ID of the request destination, the record ID, the HTTP status, etc.

The recorded items change according to the value of "SysLogsSchemaVersion" as follows.

SysLogsSchemaVersion Recorded items
1 (default) No additional columns are recorded.
2 Api, SiteId, ReferenceId, ReferenceType, Status, and Description in "Additional Columns" below are recorded.
3 In addition to the items of "2", TenantId (tenant ID) is recorded. The maximum length of UserHostAddress (user address) is extended from 16 to 50 characters, so IPv6 addresses can be recorded without truncation. For the differences in displayed logs by tenant, refer to "Differences in Displayed Logs by Tenant" in "System Log Management Function".

Cautions

  1. When running CodeDefiner, please take a backup of the database before running it. CodeDefiner recreates the SysLogs table and copies all existing logs. If the current number of records in the SysLogs table is large, it may take a long time to run CodeDefiner and may use a large amount of database space.
  2. If you change "SysLogsSchemaVersion" in the parameter "Rds.json" to a larger value, then change it back to a smaller value and run CodeDefiner, the additional columns will be deleted. Changing from "3" back to "2" deletes the TenantId column, and changing from "2" back to "1" deletes the Api, SiteId, and other columns. The deleted values are not restored even if you change the value back again. Be careful not to merge the parameter file incorrectly.
  3. Changing "SysLogsSchemaVersion" from "3" back to "2" or lower is not recommended. If you have no choice but to change it back, back up the SysLogs table beforehand, truncate UserHostAddress (user address) values of 17 characters or more to 16 characters or less, and then run CodeDefiner.
  4. Logs recorded before "SysLogsSchemaVersion" is changed to "3" have the TenantId (tenant ID) "0". When you operate multiple tenants, these logs are not displayed to "Privileged Users" of tenants other than the protected tenant.

Limitations

  1. The status code "401" is recorded only when "LoginFailure" in "SysLog.json" is true.
  2. The status code "403" is recorded only when the recorded table and the time limited table are accessed. If an unauthorized user accesses a folder, it is recorded as "404".

Prerequisites

  1. To reference the "System Log Management" screen, "Privileged User" is required.

Setting Procedure

  1. Change "SysLogsSchemaVersion" in the parameter "Rds.json" to "2" or "3". If you are already using "2", change it to "3" and follow the same steps.
  2. Run CodeDefiner.
  3. Verify that a log showing that the definition of the SysLogs table has been changed is output to the console.
  4. Check the SysLogs table and verify that the column has been added.

CodeDefiner Execution Result

> dotnet Implem.CodeDefiner.dll _rds
<INFO> UsersConfigurator.Execute: Implem.Pleasanter_Owner
<INFO> UsersConfigurator.Execute: Implem.Pleasanter_User
~Omitted~
<INFO> Tables.MigrateTable: SysLogs
<INFO> Tables.CreateTable: SysLogs
<INFO> Tables.MigrateTable: SysLogs_deleted
<INFO> Tables.CreateTable: SysLogs_deleted
<INFO> Tables.MigrateTable: SysLogs_history
<INFO> Tables.CreateTable: SysLogs_history
~Omitted~
<SUCCESS> Starter.ConfigureDatabase: Database configuration has been completed.
<SUCCESS> Starter.Main: All of the processes have been completed.

Additional Columns

Extending the system log adds six columns (Api, SiteId, ReferenceId, ReferenceType, Status, and Description) when "SysLogsSchemaVersion" is "2", and seven columns including TenantId when it is "3". For the content of each column, see "About the contents of the operation log (SysLogs table)".

When you set "SysLogsSchemaVersion" to "3", the maximum length of UserHostAddress (user address) is extended from 16 to 50 characters, so IPv6 addresses can be recorded without truncation. If it is "2" or less, only the first 16 characters are recorded.

Status Code and Details

One of the following status codes is output.

Status value Description Example of Description
200 OK: When the request was processed successfully (NULL)
400 Bad Request: General operation error ResultValidators.OnUpdating:line 514:Record 99999 was locked by Administrator on 2023/07/07 12:00:00.
401 Unauthorized: When authentication failed UserModel.LoginFailureLog:line 4403:The specified login ID or password is invalid.
403 Forbidden: When an unauthorized site is accessed ResultValidators.OnCreating:line 216:The specified information was not found.
404 Not Found: When the web page cannot be found ItemModel.Index:line 228:The specified information was not found.

Supported Versions

Supported versions Body
1.5.10.0 and later Added "3" to "SysLogsSchemaVersion" (added TenantId, extended the maximum length of UserHostAddress to 50 characters)

Rds.json